Frequently asked questions

Still looking for an answer?

Nominal voltage is 51.2 V, made from 16 cells (3.2 V nominal each).
Full charge (max) is 58.4 V → ~3.65 V per cell.
Discharge cutoff (min) is 40 V → ~2.5 V per cell 

Standard charge/discharge: 50 A (≈ 0.25 C).
Max continuous charge/discharge: 100 A (≈ 0.5 C), only at temperatures ≥ 10 °C(51.2V-300Ah is 200A)
BMS will shut off charging/discharging beyond the limits.

Fast charging within the design specs (up to 0.5 C) is acceptable. Going above can stress the battery, reduce cycle life, or trigger BMS protection 

No, there are no hidden costs. All charges, including taxes and shipping (if applicable), are clearly displayed at checkout. We value transparency and aim to provide a hassle-free shopping experience.

Our chargers are compatible with all Qi-enabled devices, including a wide range of smartphones and accessories. We recommend checking your device’s specifications to ensure wireless charging support.

BMS performs passive balancing automatically when a cell hits ~3.40 V.
SOC LED indicators show ranges: 0–25%, 25–50%, 50–75%, ≥ 75%.
LCD shows voltage, current, temperature, and balance status.

Series wiring is not recommended unless done by the manufacturer.
To expand capacity or voltage, it’s safer to use fully compatible modules managed by same-series BMS (max 16 units parallel).
Improper series/parallel wiring may cause imbalance, risk, or invalidated warranty .

No. Lead‑acid chargers operate at lower voltages (≈ 2.3–2.45 V per cell), which results in undercharging and no proper balance—this shortens life and affects capacity. Use a charger designed for LiFePO₄ chemistry (≈ 3.6–3.65 V per cell) 

LiFePO₄ chemistry offers higher thermal and chemical stability versus other lithium-ion types.
It’s significantly more resistant to thermal runaway; cell thermal runaway occurs at around 220–240 °C, much higher than NMC‐type cells (~160–230 °C) 
Still, avoid physical damage, overcharging, and exposure to extreme temperatures.
Don’t leave it charging unattended, and use only manufacturer-approved chargers and equipment.

Keep discharge depth ≤ 80% (avoid full cycles regularly).
Operate and store at moderate temperatures (~25 °C ideal).
Avoid charging below freezing, and don’t overcharge beyond cutoff voltages.